Parameters

Settings with presence detector

Parameters

Setting choices, factory setting

Explanations

Brightness measurement mode

Measurement at mounting location, measurement of room brightness

Factory setting: measurement at mounting location

If the brightness measurement is set to "Measurement at mounting location", the light falling on the sensor is measured directly.

If the brightness measurement is set to "Measurement of the room brightness", the brightness in the room is measured.

Presence recording

Off, on

Factory setting: off

With the function activated, the device sends an additional telegram brightness-independent that has no influence on the switching state of the linked loads, but is used by the JUNG HOME Gateway to trigger functions in the rest of the smart home system.

Recording setting sensors A to C

0, 25, 50, 75, 100%

Factory setting: sensors A to C 100%

Adjustable in the device detail view graphically for each sensor A to C individually in 5 stages. To limit the detection range to 120° or 240°, set the sensitivity of the areas to be deactivated to 0%.

Location

Inside, outside

Factory setting: inside

Set this setting to outdoors to further reduce the sensitivity of the sensor if the device is used in exteriors or in surroundings with interference sources.

Brightness threshold

5 ... 1,000 lx and daytime operation

Factory setting: 150 lx

Brightness value below which the load is switched on when a movement is detected.

In the "Daytime operation" setting, the device reacts to every movement brightness-independent.

Walking test

Off, on for 5 min

Factory setting: off

The walking test can be used to test whether the detection range and the sensitivity of the sensors are correctly set. Where movements are detected, the status LED lights red and there is a signal in the JUNG HOME app. Linked lighting switches in accordance with the current configuration. The function deactivates independently after approx. 5 minutes.

Operating lock

No lock, lock factory reset

Factory setting: no lock

Lock factory reset: prevents resetting at the device and thus removal from the project and recoupling by unauthorised persons. After mains voltage return, the lock for the factory reset remains inactive for 2 minutes.

Operation using the app is still possible. The operating lock cannot be deactivated at the device.

Constant light regulation**

Off, on

Factory setting: off

With the convenience function, a dimmable room or desk lighting can be regulated in such a way that the presence detector mounted over the workplace ensures a constant brightness despite variations in brightness outside. The presence detector determines the brightness value from artificial light and daylight. This is constantly maintained at the set brightness by controlling linked dimming and DALI inserts as appropriate.

Constant light regulation brightness**

10 ... 2,000 lx

Factory setting: 600 lx

With "constant light regulation" activated, the JUNG HOME presence detector regulates the linked dimmer and DALI inserts to this set value.

** Available in future via update. Notes on updates and schedules can be found at www.jung.de/JUNGHOME

Settings for automatic functions

Parameters

Setting choices, factory setting

Explanations

Time programs

Load state, time and days of the week

Depending on the system insert, the load state can be changed at specified times (days of the week and time).

Astro timer

Off, sunrise or sunset

Factory setting: off

The astro timer provides the sunrise and sunset times in the course of a calendar year. Depending on the location, load states can be changed with the position of the sun, for example so that exterior lighting can be switched on at sunset and switched off again at sunrise.

Astro timer time shift

0 (off) ... 120 minutes before or after sunrise and sunset

Factory setting: off

Astro times reflect the sunrise and sunset times in the course of a calendar year.

If there is a need to run the time program in the morning before dawn or only when it is completely bright, this can be implemented using the "sunrise" shift.

If there is a need to run the time program in the evening before twilight or only when it is completely dark, this can be implemented using the "sunset" shift. Shifts the time the load is triggered by the set value.

Astro timer threshold

Off, earliest time, latest time

Factory setting: off

To restrict the time period of an astro timer to an earliest and/or latest running time.

In this way, for example, the garden lighting can be switched off at 21:00 at the latest, even if sunset is not until 22:00.

Set location

Geographical location

The astro timer in the JUNG HOME devices requires the geographical location of the project for the calculation of the sunrise and sunset times. The calculation of the astro timer for the localised position is carried out once a week.

Automatic functions for load output 2 with multi-channel devices will be available in the future with an update (you can find notes on updates and dates at www.jung.de/JUNGHOME).

Additional settings for switch inserts

Parameters

Setting choices, factory setting

Explanations

Switch-on delay

0 s (off) ... 240 min

Factory setting: off

Switches on the load after a switch-on command delayed by this value. Repeated switch-on commands during an existing delay do not restart the delay time. If the load has not yet been switched on due to the delay, when a switch-off command comes, the load remains off.

Switch-off delay

0 s (off) ... 240 min

Factory setting: off

Switches off the load after a switch-off command with a delay of this value. A switch-off command during an existing delay switches off the load immediately. If the load has not yet been switched off due to the delay when a switch-on command comes, then the load will remain on.

Switch-off warning

Off, on

Factory setting: off

If there is an active switch-off warning, the light is not switched off immediately after expiry of the run-on time (load). Blinking three times with a spacing of 10 seconds indicates that the light is about to be switched off. The run-on time is extended by approx. 30 seconds as a result. If a movement is detected by a linked JUNG HOME sensor cover during the switch-off warning, or it is switched on again with the operation of a satellite unit or linked JUNG HOME operating cover, the run-on time is restarted and the light stays on.

Run-on time (load)

0 s (off) ... 240 min

Factory setting: off

Ensures that the load does not permanently remain switched on after a switch-on command but is switched off after expiry of the run-on time.

If a movement is detected by a linked JUNG HOME sensor cover during the run-on time, or it is switched on again with the operation of a satellite unit or linked JUNG HOME operating cover, the run-on time is restarted and the light stays on.

Early switching off of the load during an active run-on time is only possible if the "Manual switching off during run-on time" parameter is set to "on" or if a disabling function (continuous OFF) is started.

Manual switching off during run-on time

Off, on

Factory setting: on

If this parameter is set to "on" during an active run-on time (load), it is possible to manually switch off the load.

With an automatic stairway lighting controlled by JUNG HOME operating and/or sensor covers, this parameter should be set to "off" so that the light cannot be switched off by a second person.

Invert switching output

Off, on

Factory setting: off

Inverts the switching output from 1-way NO contact function (on = switching output closed) to 1-way NC contact function (on = switching output open).

This parameter only inverts the behaviour of the load output. Neither the switching commands from JUNG HOME operating or sensor covers nor the representation in the app are taken into account.

Minimum switching repeat time

100 ms ... 10 s

Factory setting: 100 ms

Limits the switching speed of the device by increasing the value, in order to protect the connected load, for example. Only when the set time has elapsed is switching possible again. The last command during the blocking time is executed after a delay. The switching repeat time starts after each switching operation.

Behaviour after mains voltage return

Switched off, switched on, previous state

Factory setting: switched off

Behaviour of the load output after mains voltage return.

Note: do not use the "Switched on" setting in combination with electrical loads that can lead to physical danger or to property damage.

Disabling function (forced guidance)

Deactivated, continuous ON, continuous OFF, ON/OFF for fixed time

Factory setting: deactivated

The disabling function switches the load output to the desired state and locks it against control by the movement sensor, satellite unit operation, time programs and wireless control by the app and other JUNG HOME devices. The lock applies for an adjustable time or until the disabling function is deactivated.

Additional settings with dimming inserts/DALI inserts

Parameters

Setting choices, factory setting

Explanations

Switch-on delay

0 s (off) ... 240 min

Factory setting: off

Switches on the load after a switch-on command delayed by this value. Repeated switch-on commands during an existing delay do not restart the delay time. If the load has not yet been switched on due to the delay, when a switch-off command comes, the load remains off.

Switch-off delay

0 s (off) ... 240 min

Factory setting: off

Switches off the load after a switch-off command with a delay of this value. A switch-off command during an existing delay switches off the load immediately. If the load has not yet been switched off due to the delay when a switch-on command comes, then the load will remain on.

Switch-off warning

Off, on

Factory setting: off

If there is an active switch-off warning, the light is not switched off immediately after expiry of the run-on time (load). The light is initially dimmed to minimum brightness within 30 seconds. The run-on time is extended by approx. 30 seconds as a result. If a movement is detected by a linked JUNG HOME sensor cover during the switch-off warning, or it is switched on again with the operation of a satellite unit or linked JUNG HOME operating cover, the run-on time is restarted and the light switches back to the switch-on brightness.

Run-on time (load)

0 s (off) ... 240 min

Factory setting: off

Ensures that the load does not permanently remain switched on after a switch-on command but is switched off after expiry of the run-on time.

If a movement is detected by a linked JUNG HOME sensor cover during the run-on time, or it is switched on again with the operation of a satellite unit or linked JUNG HOME operating cover, the run-on time is restarted and the light stays on.

Early switching off of the load during an active run-on time is only possible if the "Manual switching off during run-on time" parameter is set to "on" or if a disabling function (continuous OFF) is started.

Manual switching off during run-on time

Off, on

Factory setting: on

If this parameter is set to "on" during an active run-on time (load), it is possible to manually switch off the load.

With an automatic stairway lighting controlled by JUNG HOME operating and/or sensor covers, this parameter should be set to "off" so that the light cannot be switched off by a second person.

Dimming range (min-max)

0 ... 100%

Factory setting: 5 ... 100%

Specifies the dimming range. The minimum dimming value is mainly dependent on the lamp used and should be determined by testing.

Switch-on brightness

5 ... 100% or last value

Factory setting: 100%

By entering a value, the light is switched on at this brightness with a switch-on command.

Last value, the light is switched on at the brightness that was last set.

Colour temperature range (min-

max) (only with DALI insert)

2,000 ... 10,000 K

Factory setting: 2,700 ... 6,500 K

Specifies the adjustable colour temperature range. The minimum and maximum values depend on the colour temperature range of the lamp used and can be found from its data sheet or by trial and error.

Switch-on colour temperature (only with DALI insert)

2,000 ... 10,000 K

Factory setting: 2,700 K

If a value is entered, the light will be switched on at this colour temperature by a switch-on command.

Last value: the light will be switched on to the last set colour temperature.

Warm dimming (only with DALI insert)

Off, on

Factory setting: off

If the function is active, the colour temperature will be changed according to a saved characteristic curve when dimming.

When turning up the brightness, the colour temperature is increased towards cold white, and when reducing the brightness it is reduced towards warm white.

Hotel function**

Off, on

Factory setting: off

This convenience function prevents it, for example in hotel corridors, becoming completely dark after the run-on time has expired or the light is manually switched off. When the function is active, it is switched between two brightness values rather than between ON/OFF. When switching on, the light uses the switch-on brightness, and when switching off it uses the brightness in the hotel function.

Brightness hotel function**

5 ... 100%

Factory setting: 20%

Specifies the reduced brightness that the light is switched to with the "hotel function" activated after the run-on time has expired or the light is manually switched off. The entry in percent refers to the maximum brightness of the dimming range.

Night light function**

Off, on

Factory setting: off

This convenience function, which can be used with a time program, can ensure that the lighting in a hallway or bathroom switches on at night with a low brightness to prevent unpleasant dazzling. With the function activated, the light is not switched on with a switch-on command to the switch-on brightness, but to the set brightness in the night light function.

Night light function brightness**

5 ... 100%

Factory setting: 20%

Specifies the reduced switch-on brightness that the light is switched on at with the "night light function" activated. The entry in percent refers to the maximum brightness of the dimming range.

Behaviour after mains voltage return

Switched off, switched on, previous state, adjustable

Value

Factory setting: switched off

Behaviour of the load output after mains voltage return.

Disabling function (forced guidance)

Deactivated, continuous ON, continuous OFF, ON/OFF for fixed time

Factory setting: deactivated

The disabling function switches the load output to the desired state and locks it against control by the movement sensor, satellite unit operation, time programs and wireless control by the app and other JUNG HOME devices. The lock applies for an adjustable time or until the disabling function is deactivated.

** Available in future via update. Notes on updates and schedules can be found at www.jung.de/JUNGHOME