Parameters

Display settings

Parameters

Setting choices, factory setting

Explanations

Local display

Setpoint temperature, actual temperature, time

Factory setting: setpoint temperature

Setpoint temperature:

the display indicates the setpoint temperature.

Actual temperature:

the display indicates the actual temperature. When displaying the actual temperature, the temperature sensor symbol or the framed temperature sensor symbol is shown in the display.

Time:

the device indicates the current time.

In the actual temperature display mode or the time display mode, the setpoint temperature can be displayed with a short press on the - or + button.

In the set temperature indication mode or the actual temperature indication mode, the current time can be displayed as long as the button is pressed by pressing the [OK symbol] or [ESC symbol] button for more than 1 second.

Display timeout

After 2 minutes, constant display

Factory setting: after 2 minutes

After 2 minutes:

The display remains illuminated for a duration of 2 minutes after the last operation and then switches off.

Constant display:

the display remains on permanently.

Operating lock

No lock, factory reset lock, configuration lock on device, button lock, operating lock

Factory setting: no lock

Factory reset lock:

Prevents resetting at the device and thus removal from a project and recoupling by unauthorised persons. This lock cannot be deactivated at the device. After mains voltage return, the lock for the factory reset remains inactive for 2 minutes.

Configuration lock at device:

Prevents access to the regulation parameters that can be set via the display. Additionally prevents the use of the button lock that can be activated via the display. This lock should be activated in a hotel room, for example, so that the guest cannot accidentally change the configurations or lock the display. This lock cannot be deactivated at the device.

Button lock:

Prevents operation at the device. This lock can be used, for example, to clean the display without accidentally changing the configurations. This lock can be activated/deactivated by pressing - and AUTO on the device for 1 second.

Operating lock

Completely prevents any operation at the device. This lock can be used, for example, to temporarily limit manual access. This lock cannot be deactivated at the device.

Operation using the app is still possible with all locks

Settings for automatic functions

Parameters

Setting choices, factory setting

Explanations

Automatic operation / manual operation

Automatic operation, manual operation

Factory setting: automatic operation

Automatic operation: in automatic operation, the time program specifies the respective next setpoint temperature. Additionally in automatic operation, a new setpoint temperature can be specified using the - or + buttons on the device or using the app, but which will only be used until the next switching time.

Manual operation: in manual operation, all time programs are deactivated and the device is permanently regulated to the specified setpoint temperature.

Time programs

Temperature, time and days of the week

It is possible to switch to a new setpoint temperature at specified times (days of the week and time).

Astro timer

Off, sunrise or sunset

Factory setting: off

The astro timer provides the sunrise and sunset times in the course of a calendar year. Depending on the location, setpoint temperatures can be adjusted according to the position of the sun.

Astro timer time shift

0 (off) ... 120 minutes before or after sunrise and sunset

Factory setting: off

Astro times reflect the sunrise and sunset times in the course of a calendar year.

If there is a need to run the time program in the morning before dawn or only when it is completely bright, this can be implemented using the "sunrise" shift.

If there is a need to run the time program in the evening before twilight or only when it is completely dark, this can be implemented using the "sunset" shift. Shifts the time for the temperature change by the set value.

Astro timer threshold

Off, earliest time, latest time

Factory setting: off

To restrict the time period of an astro timer to an earliest and/or latest running time.

Set location

Geographical location

The astro timer in the JUNG HOME devices requires the geographical location of the project for the calculation of the sunrise and sunset times. The calculation of the astro timer for the localised position is carried out once a week.

Temperature regulation settings

Parameters

Setting choices, factory setting

Explanations

Comfort temperature

12 °C ... 30 °C

Factory setting: 21 °C

Setpoint for the comfort temperature.

Note: depending on the "Minimum adjustable temperature value" and "Maximum adjustable temperature value", the setting range is changed.

ECO temperature

11 °C ... 25 °C

Factory setting: 18 °C

Setpoint for the ECO temperature.

Note: depending on the "Minimum adjustable temperature value" and "Maximum adjustable temperature value", the setting range is changed.

Frost protection temperature

5 °C ... 10 °C

Factory setting: 7 °C

Setpoint for the frost protection temperature.

This parameter defines the lowest temperature that can be regulated to.

Cooling temperature**

5 °C ... 30 °C

Factory setting: 24 °C

Setpoint of the cooling temperature.

Maximum floor temperature

10 °C ... 45 °C

Factory setting: 35 °C

In order to prevent overheating of the floor, an external temperature sensor can be used that switches off the underfloor heating when the maximum floor temperature stored here is exceeded. If the temperature goes below this value again, the underfloor heating system switches on again.

Minimum adjustable temperature value

5 °C ... 25 °C

Factory setting: 5 °C

Setting of the minimum temperature setpoint for comfort temperature, ECO temperature and holiday temperature. Independently of this parameter, the frost protection temperature is the lowest temperature that can be regulated to.

Maximum adjustable temperature value

12 °C ... 30 °C

Factory setting: 30 °C

Setting of the maximum temperature setpoint for comfort temperature, ECO temperature and holiday temperature.

Heating and cooling

On, off

Factory setting: off

To activate cooling using the cooling input on the system insert.

Note: if it is not possible to activate and deactivate cooling using the system insert, a wire bridge can be created in the system insert between L and the cooling input. In this case, cooling can be activated immediately using the "On" setting and deactivated with "Off".

Using the JUNG HOME temperature sensor**

On, off

Factory setting: off

A linked JUNG HOME temperature sensor can alternatively be selected as an internal temperature sensor as the source of the actual temperature.

Temperature sensor

Internal sensor, wired external temperature sensor, internal sensor and wired external temperature sensor

Factory setting: internal sensor

Internal sensor:

the room temperature is measured using the internal temperature sensor or a JUNG HOME temperature sensor if taught in.

Wired external temperature sensor:

The room temperature is measured using the external temperature sensor that can only be connected to the room thermostat insert. The internal temperature sensor is deactivated.

Internal sensors and wired external temperature sensor:

The room temperature is measured using the internal temperature sensor or a JUNG HOME temperature sensor (if connected). The floor temperature is measured with the external temperature sensor that can only be connected to the room thermostat insert in order to enable the measurement of the maximum floor temperature.

Temperature sensor offset

Offset setting: - 5 °C ... +5 °C

If the displayed actual temperature deviates from the measured room temperature, a correction value (offset value) can be entered. The actual temperature is corrected by the offset value.

Controller output

PWM control, two-point control

Factory setting: PWM control

Pulse width-modulated control (PWM): the output is not continuously activated, but for a certain time (pulse width) which depends on the temperature difference between the setpoint and actual temperature. With this method, the actual temperature is increasingly approaching the setpoint temperature. The cycle time is 15 minutes.

Two-point control: the output remains switched on until the specified setpoint temperature is exceeded by 0.5 °C. The output is not switched on again until the temperature goes below the setpoint by 0.5 °C.

Valve adjustment

Normally closed (NC), normally open (NO)

Factory setting: normally closed (NC)

With this parameter, an adjustment of the control output to the electrothermal valve drives in use is undertaken.

Normally closed (NC): the respective motor is normally closed.

Normally open (NO): the respective motor is normally open.

Temperature drop detection

On, off

Factory setting: on

The temperature drop detection ensures that where there is a large reduction of temperature, e.g. after a window is opened, the system switches to the frost protection temperature for a maximum of 30 minutes.

Optimised heating up

On, off

Factory setting: on

The optimised heating up ensures that heating is started a maximum of 4 hours before the switching time so that when the switching time is reached the desired temperature has been achieved. The optimised heating up is optimised for space heaters/radiators.

** Available in future via update. Notes on updates and schedules can be found at www.jung.de/JUNGHOME