Configure the operating mode
All our JUNG HOME dimmers measure the characteristic of the connected load automatically and then select the most suitable dimming method themselves. For capacitive and ohmic loads,trailing edge phase control is usually chosen; for inductive loads leading edge phase control.
So that the dimming method is not changed accidentally using the app and lamps are damaged, it is specified in the hardware during commissioning with the mode selector push-button. An LED in the system insert signals the current selection.

LED lights green
- Automatic calibration to the load
- Trailing edge phase control for incandescent lamps, dimmable HV, LED or compact fluorescent lamps as well as dimmable electronic transformers with LV halogen or LV LED lamps
- Leading edge phase control for dimmable inductive transformers with halogen or dimmable LED lamps
- LED leading edge phase control for dimmable HV LED or compact fluorescent lamps
LED lights red
- The dimmer operates according to the trailing edge phase control principle
- Configuration for incandescent lamps, HV halogen lamps, dimmable HV LED or compact fluorescent lamps that can be dimmed according to the trailing edge phase control principle
- Dimmable electronic transformers with halogen or LED lamps
LED lights blue
- The dimmer operates according to the leading edge phase control principle
- Configuration for incandescent lamps, HV halogen lamps, dimmable HV LED or compact fluorescent lamps that can be dimmed according to the leading edge phase control principle
- Dimmable electronic transformers with halogen or LED lamps
To configure the operating mode and basic brightness, proceed as follows:
- First, ensure that the load is switched off.