Parameters

Binary input settings and Prog button

Parameters

Setting choices, factory setting

Explanations

Operating concept

E1/E2 combined, E1/E2 separate

Factory setting: E1/E2 separate

E1/E2 combined: corresponds to the "rocker" operating concept for JUNG HOME push-buttons. The E1 and E2 inputs together operate a device, an area or a disabling function. As a rule, switching edges on E1 or E2 lead to directly opposite reactions (e.g. light ON/OFF, lighter/darker, move up/move down).

E1/E2 separate: corresponds to the "button" operating concept for JUNG HOME push-buttons. The E1 and E2 inputs can be used separately with each operating a device, an area or a scene. When controlling loads or areas, the renewed switching edge on the same input leads to opposite reactions (e.g. light ON/OFF, lighter/darker, move up/stop/move down).

Input behaviour E1

Input behaviour E2

Rising edge: no reaction, switch on / increase brightness / move up / increase setpoint temperature/ stop, increase setpoint temperature with rising edge, switch off / decrease brightness / move down/ reduce setpoint temperature/ stop, toggle

Factory setting: toggle

Falling edge: no reaction, switch on / increase brightness / move up / stop / increase setpoint temperature, switch off / decrease brightness / move down / stop / reduce setpoint temperature, toggle

Factory setting: no reaction

The input behaviour can be configured independently from each other for a rising edge (voltage at input is switched on) and for a falling edge (voltage at input is switched off). The effect of the setting depends on the function of the connected load. The option "non reaction" has the effect of not changing the state of the connected device when the selected edge is detected at the binary input.

Operating lock

No lock, factory reset lock, operating lock

Factory setting: no lock

Lock factory reset: prevents resetting at the device and thus removal from the project and recoupling by unauthorised persons. After mains voltage return, the lock for the factory reset remains inactive for 2 minutes.

Operating lock: prevents normal operation at the device and thus control of the load. This lock can be used, for example, to temporarily limit manual access. Operation using the app is still possible. The operating lock cannot be deactivated at the device.

Settings for load control and displaying energy consumption

Parameters

Setting choices, factory setting

Explanations

Energy consumption and operating hours of the load switched on

Read out saved measurement values in kWh for the last 24 hours, read out saved measurement values in kWh for the last 31 days, reset energy consumption and operating hours

In the app, the energy consumption and the operating hours of the load switched on since the last reset are displayed. These values can be reset to 0 to start a new measurement. The energy consumption for the last 24 hours and the last 31 days are displayed graphically. To do so, the measured power for the last 24 hours are averaged for each 60 minutes and for the last 31 days for each 24 hours and displayed as active energy in kWh.

Settings for automatic functions

Parameters

Setting choices, factory setting

Explanations

Time programs

Load state, time and days of the week

The load state can be changed at specified times (days of the week and time).

Astro timer

Off, sunrise or sunset

Factory setting: off

The astro timer provides the sunrise and sunset times in the course of a calendar year. Depending on the location, load states can be changed with the position of the sun, for example so that exterior lighting can be switched on at sunset and switched off again at sunrise.

Astro timer time shift

0 (off) ... 120 minutes before or after sunrise and sunset

Factory setting: off

Astro times reflect the sunrise and sunset times in the course of a calendar year.

If there is a need to run the time program in the morning before dawn or only when it is completely bright, this can be implemented using the "sunrise" shift.

If there is a need to run the time program in the evening before twilight or only when it is completely dark, this can be implemented using the "sunset" shift. Shifts the time the load is triggered by the set value.

Astro timer threshold

Off, earliest time, latest time

Factory setting: off

To restrict the time period of an astro timer to an earliest and/or latest running time.

In this way, for example, the garden lighting can be switched off at 21:00 at the latest, even if sunset is not until 22:00.

Set location

Geographical location

The astro timer in the JUNG HOME devices requires the geographical location of the project for the calculation of the sunrise and sunset times. The calculation of the astro timer for the localised position is carried out once a week.

Switch-on threshold

0.3 .... + 3,680 W, 1 s... 60 min

Factory setting: none

The loads for the JUNG HOME devices selected in the app are switched on when the set power value is exceeded for the set time period. This automation can be used as a master-slave function: when the switch actuator Energy detects that a connected electrical load has been switched on, a wirelessly connected second JUNG HOME device can be automatically switched on.

Switch-off threshold

0.3 .... + 3,680 W, 1 s... 60 min

Factory setting: none

The loads for the JUNG HOME devices selected in the app are switched off when the set power value is not reached for the set time period. This automation can serve as a master-slave function: if the switch actuator Energy detects that a connected electrical load has gone into standby, this device can be automatically disconnected from the power supply.

Switch actuator settings

Parameters

Setting choices, factory setting

Explanations

Switch-on delay

0 s (off) ... 240 min

Factory setting: off

Switches on the load after a switch-on command delayed by this value. Repeated switch-on commands during an existing delay do not restart the delay time. If the load has not yet been switched on due to the delay, when a switch-off command comes, the load remains off.

Switch-off delay

0 s (off) ... 240 min

Factory setting: off

Switches off the load after a switch-off command with a delay of this value. A switch-off command during an existing delay switches off the load immediately. If the load has not yet been switched off due to the delay when a switch-on command comes, then the load will remain on.

Switch-off warning

Off, on

Factory setting: off

If there is an active switch-off warning, the light is not switched off immediately after expiry of the run-on time (load). Blinking three times with a spacing of 10 seconds indicates that the light is about to be switched off. The run-on time is extended by approx. 30 seconds as a result. If a movement is detected by a linked JUNG HOME sensor cover during the switch-off warning, or it is switched on again with the operation of a satellite unit or linked JUNG HOME operating cover, the run-on time is restarted and the light stays on.

Run-on time (load)

0 s (off) ... 240 min

Factory setting: off

Ensures that the load does not permanently remain switched on after a switch-on command but is switched off after expiry of the run-on time.

If a movement is detected by a linked JUNG HOME sensor cover during the run-on time, or it is switched on again with the operation of a satellite unit or linked JUNG HOME operating cover, the run-on time is restarted and the light stays on.

Early switching off of the load during an active run-on time is only possible if the "Manual switching off during run-on time" parameter is set to "on" or if a disabling function (continuous OFF) is started.

Manual switching off during run-on time

Off, on

Factory setting: on

If this parameter is set to "on" during an active run-on time (load), it is possible to manually switch off the load.

With an automatic stairway lighting controlled by JUNG HOME operating and/or sensor covers, this parameter should be set to "off" so that the light cannot be switched off by a second person.

Invert switching output

Off, on

Factory setting: off

Inverts the switching output from 1-way NO contact function (on = switching output closed) to 1-way NC contact function (on = switching output open).

This parameter only inverts the behaviour of the load output. Neither the switching commands from JUNG HOME operating or sensor covers nor the representation in the app are taken into account.

Minimum switching repeat time

100 ms ... 10 s

Factory setting: 100 ms

Limits the switching speed of the device by increasing the value, in order to protect the connected load, for example. Only when the set time has elapsed is switching possible again. The last command during the blocking time is executed after a delay. The switching repeat time starts after each switching operation.

Behaviour after mains voltage return

Switched off, switched on, previous state

Factory setting: off

Behaviour of the load output after mains voltage return.

Note: do not use the "Switched on" setting in combination with electrical loads that can lead to physical danger or to property damage.

Disabling function (forced guidance)

Deactivated, continuous ON, continuous OFF, ON/OFF for fixed time

Factory setting: deactivated

The disabling function switches the load output to the desired state and locks it against control by the movement sensor, satellite unit operation, time programs and wireless control by the app and other JUNG HOME devices. The lock applies for an adjustable time or until the disabling function is deactivated.