Parameters

Binary input settings and Prog button

Parameters

Setting choices, factory setting

Explanations

Operating concept

E1/E2 combined, E1/E2 separate

Factory setting: E1/E2 separate

E1/E2 combined: corresponds to the "rocker" operating concept for JUNG HOME push-buttons. The E1 and E2 inputs together operate a device, an area or a disabling function. As a rule, switching edges on E1 or E2 lead to directly opposite reactions (e.g. light ON/OFF, lighter/darker, move up/move down).

E1/E2 separate: corresponds to the "button" operating concept for JUNG HOME push-buttons. The E1 and E2 inputs can be used separately with each operating a device, an area or a scene. When controlling loads or areas, the renewed switching edge on the same input leads to opposite reactions (e.g. light ON/OFF, lighter/darker, move up/stop/move down).

Input behaviour E1

Input behaviour E2

Rising edge: no reaction, switch on / increase brightness / move up / increase setpoint temperature/ stop, switch off / decrease brightness / move down / reduce setpoint temperature/stop, toggle

Factory setting: toggle

Falling edge: no reaction, switch on / increase brightness / move up / stop / increase setpoint temperature, switch off / decrease brightness / move down / stop / reduce setpoint temperature, toggle

Factory setting: no reaction

The input behaviour can be configured independently from each other for a rising edge (voltage at input is switched on) and for a falling edge (voltage at input is switched off). The effect of the setting depends on the function of the connected load. The option "non reaction" has the effect of not changing the state of the connected device when the selected edge is detected at the binary input.

Operating lock

No lock, factory reset lock, operating lock

Factory setting: no lock

Lock factory reset: prevents resetting at the device and thus removal from the project and recoupling by unauthorised persons. After mains voltage return, the lock for the factory reset remains inactive for 2 minutes.

Operating lock: prevents normal operation at the device and thus control of the load. This lock can be used, for example, to temporarily limit manual access. Operation using the app is still possible. The operating lock cannot be deactivated at the device.

Settings for load control and automatic functions

Parameters

Setting choices, factory setting

Explanations

Time programs

Position, time and days of the week

It is possible to move the blind, shutter or awning to a desired position at specified times (day of the week and time).

Astro timer

Off, sunrise or sunset

Factory setting: off

The astro timer provides the sunrise and sunset times in the course of a calendar year. Depending on the location, blinds, shutters or awnings can be changed with the position of the sun, for example so that a blind is closed at sunset and opened again at sunrise.

Astro timer time shift

0 (off) ... 120 minutes before or after sunrise and sunset

Factory setting: off

Astro times reflect the sunrise and sunset times in the course of a calendar year.

If there is a need to run the time program in the morning before dawn or only when it is completely bright, this can be implemented using the "sunrise" shift.

If there is a need to run the time program in the evening before twilight or only when it is completely dark, this can be implemented using the "sunset" shift. Shifts the time of the activation of the blind, shutter or awning by the set value.

Astro timer threshold

Off, earliest time, latest time

Factory setting: off

To restrict the time period of an astro timer to an earliest and/or latest running time.

In this way, for example, a shutter can be closed at 21:00 at the latest, even if sunset is not until 22:00.

Set location

Geographical location

The astro timer in the JUNG HOME devices requires the geographical location of the project for the calculation of the sunrise and sunset times. The calculation of the astro timer for the localised position is carried out once a week.

Blinds actuator settings

Parameters

Setting choices, factory setting

Explanations

Operating mode

Shutter, blind, awning

Factory setting: shutter

Shutter: a shutter or awning is actuated for which the fabric-stretching function is not required.

Blind: a blind is actuated.

Awning: an awning is actuated for which the fabric-stretching function is required.

Running time

1 s ... 10 min

Factory setting: 2 min

Absolute time that the blind, shutter or awning requires from the fully closed to fully open end positions.

The information is necessary to be able to indicate the current position of the blind, shutter or awning and to execute precise positional movements. Therefore, this entry is carried out in the app directly after the JUNG HOME button has been added to a project - but it can be corrected later.

Slat change-over time

300 ms ... 10 s

Factory setting: 1 s (blind), 0.3 s (awning)

Absolute time for the reversal of blind slats. The fabric tightening time for the operation of awnings can be adjusted here.

Invert outputs

Off, on

Factory setting: off

Inverts the activation of the relay outputs. During inverted operation, the relay outputs "Up" and "Down" are activated in reverse. This is needed for controlling skylights, for example, or can help if a blind/shutter/awning has a reversed running direction. This parameter only reverses the behaviour of the load outputs but not the operation of the JUNG HOME push-button or the display of the running direction in the app.

Ventilation position and slat position

Ventilation position: 0 … 100%

Slat position: 0 … 100%

Factory setting: 100%

The shutter or blind stops in this position when moving down. A subsequent command to move down continues the movement to 100%.

In the "blind" operating mode, in addition, the slats are also set to the entered value.

Note: 0% in JUNG HOME corresponds to "0% closed", the "upper position", or a fully withdrawn blind/awning/shutter.

100 % in JUNG HOME corresponds to "100 % closed", the "lower position", or a fully extended blind/awning/shutter.

Minimum motor reversal time

300 ms ... 10 s

Factory settings: 1 s

Minimum pause time for a direction change. The motors can be protected by increasing the minimum reversal time.

Behaviour after mains voltage return

Move up, move down, saved position, no change

Factory settings: no change

Behaviour of the blind, shutter or awning when mains voltage returns after a power failure.

Position after mains voltage return

0 ... 100%

Position of the blind, shutter or awning after mains voltage return.

Note: only applies if "saved position" has been selected for "Behaviour after mains voltage return".

Note: 0% in JUNG HOME corresponds to "0% closed", the "upper position", or a fully withdrawn blind/awning/roller shutter.

100% in JUNG HOME corresponds to "100% closed", the "lower position", or a fully extended blind/awning/shutter.

Slat position after mains voltage return

0 ... 100%

Slat position after mains voltage return.

Note: only applies if "saved position" has been selected for "Behaviour after mains voltage return".

Disabling function (lock-out protection, wind alarm)

Deactivate, lock-out protection, wind alarm

Duration: permanent or fixed time

Factory setting: deactivated

Depending on the disabling function, when activated, the blind, the shutter or the awning is locked at the current position or first moved to a specified position.

An active disabling function prevents the operation of time programs and wireless operation via the app and other JUNG HOME devices. The lock applies for an adjustable time or until the disabling function is deactivated.

Lock-out protection: remains in the current position

Wind alarm: moves to position 0 %