Parameters
Binary input settings and Prog button
Parameters | Setting choices, factory setting | Explanations |
|---|---|---|
E1/E2 combined, E1/E2 separate Factory setting: E1/E2 separate | E1/E2 combined: corresponds to the "rocker" operating concept for JUNG HOME push-buttons. The E1 and E2 inputs together operate a device, an area or a disabling function. As a rule, switching edges on E1 or E2 lead to directly opposite reactions (e.g. light ON/OFF, lighter/darker, move up/move down). E1/E2 separate: corresponds to the "button" operating concept for JUNG HOME push-buttons. The E1 and E2 inputs can be used separately with each operating a device, an area or a scene. When controlling loads or areas, the renewed switching edge on the same input leads to opposite reactions (e.g. light ON/OFF, lighter/darker, move up/stop/move down). | |
Input behaviour E1 Input behaviour E2 | Rising edge: no reaction, switch on / increase brightness / move up / increase setpoint temperature/ stop, switch off / decrease brightness / move down / reduce setpoint temperature/stop, toggle Factory setting: toggle Falling edge: no reaction, switch on / increase brightness / move up / stop / increase setpoint temperature, switch off / decrease brightness / move down / stop / reduce setpoint temperature, toggle Factory setting: no reaction | The input behaviour can be configured independently from each other for a rising edge (voltage at input is switched on) and for a falling edge (voltage at input is switched off). The effect of the setting depends on the function of the connected load. The option "non reaction" has the effect of not changing the state of the connected device when the selected edge is detected at the binary input. |
No lock, factory reset lock, operating lock Factory setting: no lock | Lock factory reset: prevents resetting at the device and thus removal from the project and recoupling by unauthorised persons. After mains voltage return, the lock for the factory reset remains inactive for 2 minutes. Operating lock: prevents normal operation at the device and thus control of the load. This lock can be used, for example, to temporarily limit manual access. Operation using the app is still possible. The operating lock cannot be deactivated at the device. |
Settings for load control and automatic functions
Parameters | Setting choices, factory setting | Explanations |
|---|---|---|
Load state, time and days of the week | The load state can be changed at specified times (days of the week and time). | |
Off, sunrise or sunset Factory setting: off | The astro timer provides the sunrise and sunset times in the course of a calendar year. Depending on the location, load states can be changed with the position of the sun, for example so that exterior lighting can be switched on at sunset and switched off again at sunrise. | |
0 (off) ... 120 minutes before or after sunrise and sunset Factory setting: off | Astro times reflect the sunrise and sunset times in the course of a calendar year. If there is a need to run the time program in the morning before dawn or only when it is completely bright, this can be implemented using the "sunrise" shift. If there is a need to run the time program in the evening before twilight or only when it is completely dark, this can be implemented using the "sunset" shift. Shifts the time the load is triggered by the set value. | |
Off, earliest time, latest time Factory setting: off | To restrict the time period of an astro timer to an earliest and/or latest running time. In this way, for example, the garden lighting can be switched off at 21:00 at the latest, even if sunset is not until 22:00. | |
Geographical location | The astro timer in the JUNG HOME devices requires the geographical location of the project for the calculation of the sunrise and sunset times. The calculation of the astro timer for the localised position is carried out once a week. |
Switch actuator settings
Parameters | Setting choices, factory setting | Explanations |
|---|---|---|
0 s (off) ... 240 min Factory setting: off | Switches on the load after a switch-on command delayed by this value. Repeated switch-on commands during an existing delay do not restart the delay time. If the load has not yet been switched on due to the delay, when a switch-off command comes, the load remains off. | |
0 s (off) ... 240 min Factory setting: off | Switches off the load after a switch-off command with a delay of this value. A switch-off command during an existing delay switches off the load immediately. If the load has not yet been switched off due to the delay when a switch-on command comes, then the load will remain on. | |
Off, on Factory setting: off | If there is an active switch-off warning, the light is not switched off immediately after expiry of the run-on time (load). The light is initially dimmed to minimum brightness within 30 seconds. The run-on time is extended by approx. 30 seconds as a result. If a movement is detected by a linked JUNG HOME sensor cover during the switch-off warning, or it is switched on again with the operation of a satellite unit or linked JUNG HOME operating cover, the run-on time is restarted and the light switches back to the switch-on brightness. | |
0 s (off) ... 240 min Factory setting: off | Ensures that the load does not permanently remain switched on after a switch-on command but is switched off after expiry of the run-on time. If a movement is detected by a linked JUNG HOME sensor cover during the run-on time, or it is switched on again with the operation of a satellite unit or linked JUNG HOME operating cover, the run-on time is restarted and the light stays on. Early switching off of the load during an active run-on time is only possible if the "Manual switching off during run-on time" parameter is set to "on" or if a disabling function (continuous OFF) is started. | |
Off, on Factory setting: on | If this parameter is set to "on" during an active run-on time (load), it is possible to manually switch off the load. With an automatic stairway lighting controlled by JUNG HOME operating and/or sensor covers, this parameter should be set to "off" so that the light cannot be switched off by a second person. | |
Dimming method | Trailing edge phase control, leading edge phase control Factory setting: trailing edge phase control | The choice depends on the attached load (technical data) Trailing edge phase control: connection of trailing edge phase control dimmable loads. Leading edge phase control: connection of leading edge phase control dimmable LED lamps. The connection of inductive loads not permitted. |
Dimming range (min-max) | 0 ... 100% Factory setting: 5 ... 100 % | Specifies the dimming range. The minimum dimming value is mainly dependent on the lamp used and should be determined by testing. |
Switch-on brightness | 5 ... 100% or last value Factory setting: 100% | By entering a value, the light is switched on at this brightness with a switch-on command. Last value, the light is switched on at the brightness that was last set. |
Hotel function** | Off, on Factory setting: off | This convenience function prevents it, for example in hotel corridors, becoming completely dark after the run-on time has expired or the light is manually switched off. When the function is active, it is switched between two brightness values rather than between ON/OFF. When switching on, the light uses the switch-on brightness, and when switching off it uses the brightness in the hotel function. |
Brightness hotel function** | 5 ... 100% Factory setting: 20% | Specifies the reduced brightness that the light is switched to with the hotel function activated after the run-on time has expired or the light is manually switched off. The entry in percent refers to the maximum brightness of the dimming range. |
Night light function** | Off, on Factory setting: off | This convenience function, which can be used with a time program, can ensure that the lighting in a hallway or bathroom switches on at night with a low brightness to prevent unpleasant dazzling. With the function activated, the light is not switched on with a switch-on command to the switch-on brightness, but to the set brightness in the night light function. |
Night light function brightness** | 5 ... 100% Factory setting: 20% | Specifies the reduced switch-on brightness at which the light is switched on with the night function active. The entry in percent refers to the maximum brightness of the dimming range. |
Behaviour after mains voltage return | Switched off, switched on, previous state, set value Factory setting: off | Behaviour of the load output after mains voltage return. Note: do not use the "Switched on" setting in combination with electrical loads that can lead to physical danger or to property damage. |
Disabling function (forced guidance) | Deactivated, continuous ON, continuous OFF, ON/OFF for fixed time Factory setting: deactivated | The disabling function switches the load output to the desired state and locks it against control by the movement sensor, satellite unit operation, time programs and wireless control by the app and other JUNG HOME devices. The lock applies for an adjustable time or until the disabling function is deactivated. |
** Available in future via update: you can find notes on updates and dates at
www.jung.de/JUNGHOME