Configure actuators

The following tables illustrate which functions can be configured for which actuators.

All devices listed and the functions are linked to further information. If you would like to refer to this information in detail, please activate the appropriate link in the table.

Switching electrical loads

 

Relay switch insert, 1-channel

Electronic switch insert, 1-channel

Relay switch insert with floating contact, 1-channel

Relay switch insert, 2-channel

JUNG HOME SCHUKO® socket

JUNG HOME SCHUKO® socket Energy

JUNG HOME switch actuator 1-gang mini with 2 binary inputs

JUNG HOME Puck binary input 2-gang, 230 V

JUNG HOME Puck binary input 2-gang, battery-powered

JUNG HOME Puck dimmer 1-gang with 2 binary inputs

JUNG HOME Puck Power DALI-2 controller TW with 2 binary inputs

JUNG HOME Puck switch actuator 1-gang Energy with 2 binary inputs

JUNG HOME Puck switch actuator 2-gang with 2 binary inputs

 

1701SE

1704ESE

1701PSE

1702SE

BT..1521S..

BT..1521SE..

BTS1B2U

BTPB2U

BTPB2UB

BTPD1B2U

BTPDSTEB2U

BTPSE1B2U

BTPS2B2U

Switch-off warning

●

●

●

●

 

 

●

 

 

●

●

●

●

Switch-off threshold

 

 

 

 

 

●

 

 

 

 

●

●

 

Switch-off delay

●

●

●

●

●

●

●

 

 

●

●

●

●

Switch-on threshold

 

 

 

 

 

●

 

 

 

 

●

●

 

Switch-on delay

●

●

●

●

●

●

●

 

 

●

●

●

●

Energy consumption and operating hours of the load switched on

 

 

 

 

 

●

 

 

 

 

●

●

 

Power measurement

 

 

 

 

 

●

 

 

 

 

 

 

 

Manually switching off during the run-on time

●

●

●

●

●

●

●

 

 

●

●

●

●

Run-on time

●

●

●

●

●

●

●

 

 

●

●

●

●

Invert switching output

●

●

●

●

 

 

 

 

 

 

●

●

●

Disabling function (forced guidance)

●

●

●

●

●

●

●

 

 

●

●

●

●

Behaviour after mains voltage return

●

●

●

●

●

●

●

 

 

●

●

●

●

Control and dim lighting

 

Touch dimmer Standard LED

Touch dimmer Universal LED

2-gang touch dimmer Universal LED

Power DALI push-button controller TW

JUNG HOME Puck binary input 2-gang 230 V

JUNG HOME Puck binary input 2-gang battery-powered

JUNG HOME Puck dimmer 1-gang with 2 binary inputs

JUNG HOME Puck Power DALI-2 controller TW with 2 binary inputs

JUNG HOME Puck switch actuator 1-gang Energy with 2 binary inputs

JUNG HOME Puck switch actuator 2-gang with 2 binary inputs

 

1710DE

1711DE

1712DE

1713DSTE

BTPB2U

BTPB2UB

BTPD1B2U

BTPDSTEB2U

BTPSE1B2U

BTPS2B2U

Switch-off warning

●

●

●

●

 

 

●

●

●

●

Switch-off delay

●

●

●

●

 

 

●

●

●

●

Dimming range

●

●

●

●

 

 

●

 

 

 

Switch-on colour temperature

 

 

 

●

 

 

 

 

 

 

Switch-on brightness

●

●

●

●

 

 

●

 

 

 

Switch-on delay

●

●

●

●

 

 

●

●

●

●

Colour temperature range

 

 

 

●

 

 

 

 

 

 

Manually switching off during the run-on time

●

●

●

●

 

 

●

●

●

●

Run-on time

●

●

●

●

 

 

●

●

●

●

Night light function

●

●

●

●

 

 

●

 

 

 

Disabling function (forced guidance)

●

●

●

●

 

 

●

●

●

●

Behaviour after mains voltage return

●

●

●

●

 

 

●

●

●

●

Control blinds

 

Standard blinds insert

Universal blinds insert

JUNG HOME blinds actuator 1-gang mini with 2 binary inputs

JUNG HOME Puck blinds actuator 1-gang with 2 binary inputs

 

1730JE

1731JE

BTJ1B2U

BTPJ1B2U

Operating mode

●

●

●

●

Slat change-over time

●

●

●

●

Running time

●

●

●

●

Minimum motor reversal time

●

●

●

●

Invert switching output

●

●

●

●

Disabling function (forced guidance, lock-out protection, wind alarm)

●

●

●

●

Behaviour after mains voltage return

●

●

●

●

Switch-off warning

Astro function

Switch-off threshold

Switch-off delay

operating mode

Switch-on colour temperature

Switch-on brightness

Switch-on threshold

Switch-on delay

Energy consumption and operating hours of the load switched on

Colour temperature range

Slat change-over time

Running time

Power measurement

Manual switch-off of the run-on time

Minimum motor reversal time

Run-on time

Invert switching output

Behaviour after mains voltage return

Wind alarm

Timer function