Connecting a satellite unit

In addition to the terminals L, N and the motor connection, the universal blinds insert also has two terminals 1 and 2 for the connection of satellite units. If the 230 V mains voltage is applied to one of these inputs, the corresponding travel direction of the motor is initiated. In this way, it is possible to also control the blind with operating elements from LB Management. The motor moves as long as there is mains voltage at the satellite input.

As the satellite input "Up" can also be used for connecting a wind sensor, this has the highest priority, even with local operating elements.

The 230 V satellite unit inputs are electrically isolated from the electronics via optocouplers and are routed to the interface for the operating cover. This enables the use of different phase conductors (e.g. L1 + L2).

Mechanical and electronic satellite inputs can be connected to a satellite input. Mechanical satellites are blind buttons or switches. These are suitable for connection and provide protection against unauthorised actions. Drawbacks of the mechanical satellites are that the buttons can only be operated manually during the entire running time and switches have to be reset.

Caution!
Damage to equipment from incorrect connection!

Do not connect any motors and satellite units in parallel as the high alternating voltages produced by the motors can damage the blind inserts.